CBBMS - MARATHON, 1005

  • MSDS: CBBMS
  • Manufacturer: PARKER PAINT
  • Product Name: MARATHON, 1005
  • National Stock Number: 8010-00N024764
Product Identification

Product ID:MARATHON, 1005
MSDS Date:11/29/1994
FSC:8010
NIIN:00N024764
MSDS Number: CBBMS

Responsible Party
PARKER PAINT
3003 SOUTH TACOMA WAY
TACOMA, WA 98407
US

Emergency Phone: 800-255-3924

Info Phone: 206-473-1122

Preparer: J BURNWORTH

Cage: 9H480

Contractor
PARKER PAINT
11047 TACOMA, WA 98409 US

Telephone: 253-473-1122

Cage: 9H480

Ingredients

2 @ 68F

CAS: 8052-41-3

RTECS: WJ8925000

Fraction By Weight: 40%

OSHA PEL 500 PPM

ACGIH TLV: 100 PPM


5.1 @ 68F

CAS: 1330-20-7

RTECS: ZE2100000

Fraction By Weight: 1%

OSHA PEL 100 PPM

ACGIH TLV: 100 PPM/150STEL

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: INHAL OF HIGH CONCS OF VAPS MAY
LEAD TO NASAL IRRIT, HDCH, NAUS, ASPHY/UNCON. SKIN: RPTD CONT CAN
DEFAT SKIN CAUSING IRRIT & DERM. EYES: CONT CAN CAUSE SEV IRRIT,
REDNESS, TEARING/BLURRED VISIO N. INGEST: SWALLOWING CAN CAUSE GI
IRRIT, NAUS, VOMIT & DIARR. VOMIT CAN RSLT IN ASPIR OF MATL INTO
(EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ: LUNGS WHICH CAN CAUSE CHEM PNEUMIT.
INHAL CAN CAUSE ACUTE NERV SYS DEPRESS CHARACTERIZED BY NASAL
IRRIT, HDCH, DIZZ, CONFUSION/UNCON. CHRONIC: OVEREXP TO VAPS MAY
CAUSE KIDNEY/LIVER DMG. LAB STUDIES W/RATS HAVE SHOWN THAT PETRO
DISTIL CAUSE KIDNEY & LIVER DMG/TUMORS. SEVERAL STUDIES EVALUATING
(SUP DAT)
Medical Cond Aggravated by Exposure:NONE KNOWN AT THIS TIME.

First Aid

First Aid:INHAL: REMOVE TO FRESH AIR. IF BRTHG HAS STOPPED, APPLY ARTF
RESP. CONSULT MD. EYES: WASH W/CLEAN WATER FOR AT LEAST 15 MIN.
CONSULT MD. SKIN: WASH AFFECTED AREAS W/SOAP & WATER. REMOVE CONTAM
CLTHG. CONSULT MD IF IRRIT PERSISTS. INGEST: DRINK 1-2 GLASSES OF
WATER TO DILUTE. DO NOT INDUCE VOMIT! CONSULT MD OR POISON CONTROL
CENTER.

Fire Fighting

Flash Point Method:SCC
Flash Point:105F,41C
Lower Limits:1%
Upper Limits:7%
Extinguishing Media:USE FOAM, ALCOHOL FOAM, CARBON DIOXIDE, DRY
CHEMICAL.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPRVD SCBA & FULL PROT EQUIP
. WATER MAY BE USED TO COOL CLSD CONTRS TO PVNT PRESS BUILD-UP &
POSS AUTO-IGNIT/EXPLO WHEN EXPOS (SUP DAT)
Unusual Fire/Explosion Hazard:KEEP CONTRS TIGHTLY CLSD. ISOLATE FROM
HEAT, ELEC EQUIP, SPARKS & OPEN FLAME. CLSD CONTRS MAY EXPLODE WHEN
EXPOSED TO EXTREME HEAT. DURING EMER CNDTNS (SUP DAT)

Accidental Release

Spill Release Procedures:VENTILATE AREA. REMOVE ALL SOURCES OF IGNITION
(FLAME, HOT SURFACES, ELECTRICAL, STATIC OR FRICTIONAL SPARKS).
AVOID SKIN CONTACT AND BREATHING VAPORS. CONTAIN AND REMOVE WITH
INERT ABSORBENT AND NON- SPARKING TOOLS.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:STORE IN A COOL, WELL VENTILATED AREA
AWAY FROM SOURCES OF IGNITION. STORE LARGE QUANTITIES ONLY IN
BUILDINGS DESIGNED TO COMPLY WITH OSHA 1910.106.
Other Precautions:DO NOT TAKE INTERNALLY. KEEP OUT OF THE REACH OF
CHILDREN.

Exposure Controls

Respiratory Protection:WEAR PROPERLY FITTED NIOSH/MSHA APPRVD
VAP/PARTICULATE RESP/AIR-SUPP RESP UNLESS VENT IS ADEQ TO KEEP
AIRBORNE CONTAMINATION BELOW APPLIC OSHA, PEL OR ACGIH TLV
OCCUPATIONAL EXPOSURE LIMITS.
Ventilation:PROVIDE SUFFICIENT VENT IN VOL & PATTERN, W/EXPLO-PROOF
EQUIP TO KEEP AIR CONTAM CONC < APPLIC PEL/TLV.
Protective Gloves:RUBBER OR NEOPRENE GLOVES.
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGS .
Other Protective Equipment:ANSI APPRVD EMER EYEWASH & DELUGE SHOWER .
COVERALLS & HOODS ARE REC DURING SPRAY APPLICATION. PROT (SUP DAT)
Work Hygienic Practices:WASH HANDS BEFORE EATING OR USING THE RESTROOM.
Supplemental Safety and Health
FIRE FIGHT PROC: TO EXTREME HEAT. EXPLO HAZ: OVEREXP TO DECOMP PRODS
MAY CAUSE HLTH HAZ. EFTS OF OVEREXP: PETRO WORKERS HAVE NOT SHOWN
SIGNIFICANT INCR OF KIDNEY DMG, NOR KIDNEY/LIVER TUMORS. OTHER PR
OT EQUIP: CREAMS MAY BE USED FOR EASE OF CLEAN-UP, NOT FOR PROT.

Chemical Properties

Boiling Pt:B.P. Text:314F,157C
Vapor Pres:SEE INGS
Vapor Density:HVR/AIR
Spec Gravity:1.13 (H*2O=1)
Evaporation Rate & Reference:SLOWER THAN ETHER
Solubility in Water:INSOLUBLE
Appearance and Odor:COLORED LIQUID, WITH AN ALIPHATIC ODOR

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING MATERIALS.
Stability Condition to Avoid:EXTREME HEAT, SPARKS OR OPEN FLAME.
Hazardous Decomposition Products:INCOMPLETE COMBUSTION CAN PRODUCE
CARBON MONOXIDE.

Disposal

Waste Disposal Methods:DO NOT ALLOW MATERIAL TO CONTAMINATE GROUND
WATER SYSTEMS. ABSORB LARGE SPILLS WITH SAND, CLAY OR DIATOMACEOUS
EARTH. DISPOSE IN ACCORDANCE WITH LOCAL, STATE, AND FEDERAL
DISPOSAL REQUIREMENTS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.